Firescreen Temperature (EI)
Commercial contact
To see the information concerning the commercial contact, you must register first by clicking on this Link
Catalog
To see the information concerning the commercial contact, you must register first by clicking on this Link
Firescreen Temperature (EI)
Select the desired format and click on the download button
Share Page
Width | 5000 |
Height | 4000 |
Designed in | Netherlands |
Manufactured in | Netherlands |
EI30/EI60 Fire-resistant roller curtain.
- 60 minutes of fire resistance
- Thermal radiation max. 1 kW/m²
- Tested according to standard EN 1634-1 / EN 15269-11
- Tested according to standard EN 13501-1
- Little installation space
- Little side space
- Lightweight
Firescreen Temperature fire-resistant fire curtains are flame-resistant, limit heat radiation, and provide thermal insulation. This makes the fire curtains suitable for such uses as creating an evacuation route or an attack route for the fire brigade. When used to seal fire compartments, the curtains ensure that the curtain temperature on the non-fire side rises by at most 140°C.
FAIL SAFE OPTIONS
- Closure upon loss of power:
- GFS (Gravity Fail Safe) - In the event of power failure, the screen closes by gravity.
- EFS (Electrical Fail Safe) -In the event of power failure, the screen closes with emergency power batteries.
- FIRESCREEN CONTROL
- The control box includes the ability to connect to the fire alarm system and has LED indicators for:
- Power supply
- Active fire signal
- Maintenance
- Battery voltage (only with Firescreen Control)
OPTIONS
- Powder-coating of side guides, guard and consoles in any desired RAL colour.
- Emergency push button for EFS version.
- Smoke alarm
- Strobe light and/or buzzer
- External LED display
- 24V emergency power batteries, for GFS version prevents screen closure in the event of a short power interruption.
STANDARD SPECIFICATIONS
- Installation: On the wall.
- Application: Insulation without sprinkler system, realisation of an evacuation route, among others; meets the requirements for a fire wall.
- Function: Door closes only in the event of a fire alarm.
- Fire resistance: Tested according to standard EN 13501-2. Fire resistance classes EI130, EI230, EI160 and EI260.
- Reaction to fire: Tested according to standard EN 13501-1.
- B (almost incombustible)
- S1 (minor smoke development)
- D0 (absolutely no drop formation)
- Max. mounting surface: 5,000 x 4,000 mm (wxh)
- Material: Double-walled technical textile, filled with intumescent material Provided with a silicone-based, smoke-proof grey coating.
- Material thickness: 13 mm total thickness
- Cloth weight: 9 kg/m²
- Side guide rails + guard: Sendzimir galvanised sheet steel
- Bottom bar: Steel axis
This product is available in:
Angola Burkina Faso Burundi Benin Botswana Democratic Republic of the Congo Central African Republic Republic of the Congo Côte d'Ivoire Cameroon Cape Verde Djibouti Algeria Western Sahara Eritrea Ethiopia Gabon Ghana The Gambia Guinea Equatorial Guinea Guinea-Bissau Kenya Comoros Liberia Lesotho Libya Morocco Madagascar Mali Mauritania Mauritius Malawi Mozambique Namibia Niger Nigeria Reunion Rwanda Seychelles Sudan Saint Helena Sierra Leone Senegal Somalia South Sudan São Tomé and Príncipe Eswatini Chad Togo Tunisia Tanzania Uganda Mayotte South Africa Zambia Zimbabwe
Antarctica Bouvet Island South Georgia and the South Sandwich Islands Heard Island and McDonald Islands French Southern and Antarctic Lands
Armenia Azerbaijan Bangladesh Brunei Bhutan Cocos (Keeling) Islands China Christmas Island Georgia Hong Kong Indonesia India British Indian Ocean Territory Japan Kyrgyzstan Cambodia North Korea South Korea Kazakhstan Laos Sri Lanka Myanmar (Burma) Mongolia Macau Maldives Malaysia Nepal Philippines Pakistan Singapore Thailand Tajikistan Turkmenistan Taiwan Uzbekistan Vietnam
Andorra Albania Austria Åland Islands Bosnia and Herzegovina Belgium Bulgaria Belarus Switzerland Cyprus Czech Republic Germany Denmark Estonia Spain Finland Faroe Islands France United Kingdom Guernsey Gibraltar Greece Croatia Hungary Ireland Isle of Man Iceland Italy Jersey Liechtenstein Lithuania Luxembourg Latvia Monaco Moldova Montenegro North Macedonia Malta Netherlands Norway Poland Portugal Romania Serbia Russia Sweden Slovenia Svalbard and Jan Mayen Slovakia San Marino Ukraine Vatican City
United Arab Emirates Afghanistan Bahrain Egypt Israel Iraq Iran Jordan Kuwait Lebanon Oman Palestine Qatar Saudi Arabia Syria Türkiye Yemen
Antigua and Barbuda Anguilla Aruba Barbados Saint-Barthélemy Bermuda Caribbean Netherlands The Bahamas Belize Canada Costa Rica Cuba Curaçao Dominica Dominican Republic Grenada Greenland Guadeloupe Guatemala Honduras Haiti Jamaica Saint Kitts and Nevis Cayman Islands Saint Lucia Collectivity of Saint Martin Martinique Montserrat Mexico Nicaragua Panama Saint Pierre and Miquelon Puerto Rico El Salvador Sint Maarten Turks and Caicos Islands Trinidad and Tobago United States Saint Vincent and the Grenadines British Virgin Islands U.S. Virgin Islands
American Samoa Australia Cook Islands Fiji Federated States of Micronesia Guam Kiribati Marshall Islands Northern Mariana Islands New Caledonia Norfolk Island Nauru Niue New Zealand French Polynesia Papua New Guinea Pitcairn Islands Palau Solomon Islands Tokelau Timor-Leste Tonga Tuvalu United States Minor Outlying Islands Vanuatu Wallis and Futuna Samoa
Argentina Bolivia Brazil Chile Colombia Ecuador Falkland Islands (Islas Malvinas) French Guiana Guyana Peru Paraguay Suriname Uruguay Venezuela
To see the installation company information, please register first by clicking on this Link